Sale!

9 Units Antminer S9-Hydro + 9 APW5

10,555.00 6,999.00

9 Units AntMiner S9 Hydro + 9 APW5

1. Please click here for the installation guide. Suggested specifications for radiators, accessories and power supplies that are not purchased from us can be found in the guide.

2. Bitmain recommends the APW5 to power the Antminer S9-Hydro.

3. Bitmain recommends Radiators & Accessories for S9 Hydro to run the S9-Hydro.

4. Please note the stated information if you cannot use a 220 V input for APW5. If you are using a 110 V input for APW5, the rated power is 1300 W and will not be capable to power the S9-Hydro. If you are using a 220 V input, the rated power will be 2600 W and will be able to power the S9-Hydro.

5. Bracket for PSU is designed to fix APW5 with S9-Hydro.

 

Bulk Order Details :

9 X Antminer S9 Hydro – Brand New

9 X APW5

 

Ships from United States & United Kingdom. Most customers receive within 4-10 days

1 in stock

Description

 

Product Glance Value
Product model S9 Hydro-18.0T
Hashrate, TH/s 18.00
Power efficiency on wall @25°C, J/TH 96.00
Adapted power supply model APW5
Adapted power supply, Watt / Volt 1728W / 220V
Detailed Characteristics Value
Min Typ Max
Hashrate & Power
Hashrate, TH/s 18.00 18.40
Power efficiency on wall @25°C, J/TH (1-1) 96.0 102.7
Power efficiency on wall @40°C, J/TH (1-2) 103.2 110.4
Power on wall, W (1-3)   1728 2031
Power Supply Input Range
Power supply input voltage, V AC (2-1) 200 220 265
Power Supply input Frequency Range, Hz (2-2) 47 50 63
Power supply input current, A (2-3) 7.85 10.16
Power Supply Safety Protection
Output Overcurrent Protection, A DC (3-1) 216 225
Low Voltage Input Protection, V AC 90 100
Hardware Configuration
Quantity of hash chips 216
Quantity of hash boards 4
Networking connection mode RJ45 ethernet 10/100M
Miner Size (Length*Width*Height), mm(4-1) 360*125*190
Net weight, kg (4-2) 5.15
Noise, dBA @25°C  (4-3) 45 58
Environment Requirements
Water inlet temperature, °C    15 (5-1) 55
Water flow, L/min    5 (5-2) 15
Flow system pressure, kPa 50 300
Operation temperature, °C 0 25 40
Storage temperature, °C -40 25 85
Operation humidity, RH 5% 95%

 

(1-1) Miner test in 25°C temperature chamber. Heat exchanger and water pump power are included.

(1-2) Miner test in 40°C temperature chamber. Heat exchanger and water pump power are included.

(1-3) Typ condition: 25°C, min J/TH, typical Hashrate

Max condition: 40°C, max J/TH, max Hashrate

(2-1) Caution: Supply lower than 200V will cause APW5 protection or damage

Due to APW output power will be reduced by 50% under 200V input, and it is not enough for miner

(2-2) 220V AC Power Supply Frequency

(2-3) Typ condition: Min Power on wall, 220V AC supply

Max condition: Max Power on wall, 180V AC supply

(3-1) During 220V AC input

(4-1) Without APW5 & Heat exchanger and water pump, including the bend pipes . APW5 L*W*H(mm) = 260*125*86

(4-2) Without APW5 & Heat exchanger, pump, including the bend pipes, APW5 net weight is 2.5kg

(4-3) Typ condition: 25°C, typical J/TH, typical Hashrate

Max condition: 40°C, max J/TH, max Hashrate

(5-1) Temperature should be no less than 15°C, and at least 3°C higher than dew point

(5-2) The external water source can appropriately reduce the flow according to the actual water temperature. Under this condition, the recommendation is no less than 2L/min.

Notes: The use of outdoor water sources (cooling towers, natural water sources) will cool the system more effectively than the Radiators & Accessories. The flow rate can be adjusted accordingly, but it is recommended to be no less than 2L/min. If the flow rate is too low, it will be greatly affected by the system resistance, which may lead to uneven branch flow.

1. Please select the correct address for shipping before you submit your order because, for this batch, the shipping address and shipping method cannot be changed after the order has been submitted.

2.The shipping for this batch will start on a first-paid-first-ship basis for orders that Bitmain has received full payment for. We advise you to research and prepare in advance for the customs’ clearance in your country to avoid delays or unexpected costs.

3.Power consumption figures will vary with your PSU’s efficiency, the ambient operating temperature and the accuracy of the power meter.

4. There are 3 PCI-e connectors for +12V DC input on each hashing board and all 3 need to be connected to the PSU for the hashboard to operate. Do not connect more than one PSU to the same hashing board!

5. The power cord is not included, please find one with at least 10A from your local market. Separate power supply to control board: there is one additional 6pin PCI-e connector on the IO board which must be connected to the PSU to get power. Be sure to power on the miner only after all the 10x PCIE connectors are connected to power supply.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.